Waterproofing and Admixtures

SUPERPLASTET F

Non-Retarding, Superplasticing, Water Reducing & Strength Acclerating Admixture

Typical test results using SUPERPLASTET F at 1 litre per 100kg cement
compared with the ASTM C494 Type F Requirement.

SUPERPLASTET F

ASTM C494 Type F Requirements
Water reduction 18% 12% minimum

Compressive strength    1 day
3 days
7 days
28 days
180 days
365 days

106%
165%
150%
150%
148%
143%
140% minimum
125% minimum
115% minimum
110% minimum
100% minimum
100% minimum

Flexural strength          3 days
7 days
28 days

137%
111%
115%
110% minimum
100% minimum
100% minimum

Time of setting               Initial
Final

42 min earlier
36 min earlier
Not more than 1hr earlier or 1.5hr later
Not more than 1hr earlier or 1.5hr later
Length Change/Shrinkage -0.014 Maximum increase over control 0.010
Relative Durability 98% Minimum % of control 80.0%

SPECIFICATIONS

All concrete shall contain Cementaid SUPERPLASTET F used in strict accordance with the manufacturer's instructions. If concrete is site mixed, batch numbers of SUPERPLASTET F containers and rate of addition shall be recorded. Premixed concrete shall record the rate of SUPERPLASTET F addition on all dockets.


DOSAGE:

For high strength, water reduced concrete, SUPERPLASTET F is used at a rate of 0.8 and 1.5 litres per 100kg of cement for high strength, flowing and low heat concrete.
If only flowing concrete is required without water reduction, a dosage of 0.3-0.5 litres per 100kg will be sufficient.

OVERDOSING AND REDOSING:

Accidental overdoses do not harm the concrete strength. SUPERPLASTET F can be redosed several times to maintain to workable slump in the event of excessive delays without any detrimental effects.


INDUSTRIAL FLOOR SPECIFICATIONS - GEL CONTROL AGENT - ANTI-CORROSION IMPREGNATIONS - OIL & SOLVENT PROOFING - WATERPROOFING - RAPID HARDENING RETARDING - SURFACE TOUGHENING - MORTAR AND DAMPCOURSE ADMIXTURES, ETC.

The information and recommendations herein are, as a result of experience and testing, accurate to the best of the seller's knowledge. However, as the proposed use and the circumstances surrounding such use are not known to the seller, it does not guarantee or warrant the product's suitability in any particular instance and shall not be liable for any loss or damage consequent upon any use whatsoever unless the seller has otherwise stipulated the product's suitability for a particular use in writing signed by a Director of the seller.




       